folding nanofiber protective mask
Main raw material ,Structure and composition:
Mask (sterility) It is composed of mask body, nose clip and mask belt. Mask body is divided : surface layer, filtration layer , fine nano filtration layer , bottom layer,Skin friendly layer , total five layers.
The surface , bottom layer , and skin friendly layer of mask is Polypropylene spunbonded nonwoven fabric , filtration layer is Polypropylene melt-sprayed nonwoven fabric, fine nano filtration layer is nanofiber membrance , the nose clip is made of a plastic material,The mask belt is made of polyester and spandex yarn.
Application:
This standard is applicable to the medical working environment, filter the particulate matter in the air, block droplets, blood, body fluids, secretions and other self-absorption filter medical respirator.
Main technical indicators of products:
Filtration efficiency
When the gas flow rate is 85L/min, the filtration efficiency of the mask for non-oily particles should meet the requirements in table
sheet 1 ,Filtration efficiency class % |
|
One |
≥95 |
two |
≥99 |
Three |
≥99.97 |
Airflow resistance
For gas flow of 85L/min, the inspiratory resistance of the mask should not exceed 343.2pa (35mmH2O)
synthetic blood penetration
Spray 2mL of synthetic blood into the mask at a pressure of 10.7kpa (80mmHg). No infiltration should occur inside the mask
Surface moisture resistance
The water level on the outer surface of the mask should not be lower than the level 3 in GB/ t4745-1997
Microbiological indicator
The mask should meet the requirements of the microbial indicators in gb15979-2002, as shown in table 2
Sheet 2 Microbiological index of mask
Total number of bacterial colonies CFU/G |
coli group |
pseudomonas aeruginosa |
staphylococcus aureus |
hemolytic streptococcus |
Total number of fungal colonies |
≤200 |
undetectable |
undetectable |
undetectable |
undetectable |
≤100 |
Residual ethylene oxide
For masks sterilized by ethylene oxide, the residue of ethylene oxide should not exceed 10 g/g
flame resistance
The materials used should not be inflammable. The afterburn time should not exceed 5s
Skin irritation
The score for primary irritation of mask material should not exceed
Sterilization method: ethylene oxide sterilization. Residual ethylene oxide (g/g) ≤10
Standard:GB19083-2010
Product detail pictures:


Related Product Guide:
Organic Feed Market : Competitive landscape is moderately consolidated, with strong emphasis on innovation 2017 – 2025 | Poultry Feed Ingredients
Worldwide Probiotics in Animal Feed Market Demand Analysis 2019 | Organic Poultry Feed
We have our own product sales staff, style crew, technical group, QC staff and package staff. We now have strict high quality management procedures for each approach. Also, all of our workers are experienced in printing subject for China Supplier Dns Fine Chemicals - Medical folding nanofiber protective mask – E.Fine , The product will supply to all over the world, such as: Sweden, Oman, Costa rica, Our company offers the full range from pre-sales to after-sales service, from product development to audit the use of maintenance, based on strong technical strength, superior product performance, reasonable prices and perfect service, we will continue to develop, to provide the high-quality products and services, and promote lasting cooperation with our customers, common development and create a better future.

Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!